MAEC TOOL NEWS: MAECT-TM-010816D

TM
Precaution

Please take note of the following problem in using TM.
  • On TM V.3.xx reading projects created by TM V.2.xx


  1. Versions Concerned
    TM V.3.00 -- V.3.11

  2. Description
    When the Debug button on the Project bar is clicked, TM invokes the registered emulator debugger, PD32R, PD308, PD30, PD79, PD77, or PD38 (hereafter called PDxx); or the registered simulator debugger, PD32RSIM, PD308SIM, PD30SIM, PD79SIM, PD77SIM, or PD38SIM (hereafter called PDxxSIM). Then, PDxx or PDxxSIM automatically downloads the load module file.
    In some cases, however, PDxx or PDxxSIM would not download the load module file, and the following error message will appear.
    -----------------------------------------------------------------
     "ERROR xxxxxx: Unable to read Load Module File (xxxx)"
    -----------------------------------------------------------------
  3. Conditions
    This problem occurs if the following two conditions are satisfied:
    (1) PDxx or PDxxSIM has been registered in TM.
    (2) After the product concerned reads projects created by TM V.2.xx, the Debug button is clicked.

  4. Workaround
    When the product concerned has read projects created by TM V.2.xx, execute the [File] -> [Save] command in Project Editor. Then press the Debug button to download the load module.

  5. Schedule of Fixing the Problem
    We plan to fix this problem in our next release.