Everything
5.1 Internal Errors

Table 5.1

Internal Errors

C0100001

[Message]

xxx is empty.

C0100002

[Message]

xxx is too large.

C0100003

[Message]

Unexpected xxx is specified.

C0149999

[Message]

Internal Error : Exceeds check_folder limit (1024).

[Explanation]

This appears when the limit value (1024) of target on a start process check was exceeded.

[Message]

Internal Error : VIA_ENV_SETUP is not correct.

[Explanation]

This appears when the installer for installing a required environment calls the integrated installer, and an integration installer couldn't be started right.

C0171000

[Message]

An internal error occurred.

Failed to get a license.

xxx

C0171001

[Message]

An internal error occurred.

Failed to send license request.

xxx

C0171002

[Message]

An internal error occurred.

Failed to send license request.

C0190000

[Message]

Specified device is invalid.

C0190001

[Message]

xxx is empty.

C0190002

[Message]

xxx is too large.

C0190003

[Message]

xxx is too small.

C0600000

[Message]

Internal error.

C0600001

[Message]

Illegal argument. (xxx=yyy)

C0600002

[Message]

Illegal argument. (xxx=nullptr)

C0600003

[Message]

It has already registered.

C0600004

[Message]

It is not registered.

C0602000

[Message]

Already connected.

C0602001

[Message]

Already disconnected.

C0602002

[Message]

A device file is non-setting.

C0602003

[Message]

Unhandled exception occurred.

C0602100

[Message]

Please check connection with the target board.

C0602101

[Message]

Please check connection with the target board, and power on it.

C0602103

[Message]

Please disconnect the target board.

C0602104

[Message]

Please power off the target board, and disconnect it.

C0602200

[Message]

Incorrect ID Code. Flash memory was erased.

C0602201

[Message]

Disabled ID Code. Flash memory was erased.

C0602202

[Message]

Incorrect ID Code.

[Explanation]

This message appears when the security ID written in flash memory does not match the security ID specified by the debug tool.

[Action by User]

Confirm whether the security ID setting is the same in the flash memory and debug tool with reference to the following.

 

[RL78]

-

Security ID written in flash memory

(a) When set in the user program

The security ID is the value specified in addresses 0xC4 to 0xCD.

(b) When set by the build tool's common option

The security ID is the value specified by [security ID] in the [Device] category within the [Common Options] tab in the build tool property.

 

When both (a) and (b) are set, the setting of (b) is given priority.

 

-

Security ID specified by the debug tool

The security ID is the value specified by [Flash] -> [ID code] in the [Connect Settings] tab on the Property panel of the debug tool.

If the user has forgotten the security ID to enable debugging, erase the flash memory and set the security ID again. The security ID after the flash memory has been erased is all 0s.

 

For details on the security ID in the flash memory and debug tool, refer to the following:

E1/E20/E2 Emulator, E2 Emulator Lite Additional Document for User’s Manual (Notes on Connection of RL78) -> “Setting a Security ID”

 

[RH850]

-

Security ID (ID code) written in flash memory

The ID code is stored in an extended area and it is set by a flash programming tool. For details, refer to the documentation of the flash programming tool in use.

 

-

Security ID (ID code) specified by the debug tool

The security ID is the value specified in [Security ID] of the [Flash] category in the [Connect Settings] tabbed page on the Property panel of the debug tool.

If you have forgotten the security ID (ID code), erase flash memory and set the security ID again. After flash memory has been erased, the security ID becomes all Fs.

C1700000

[Message]

Failed to execute the callback event (ID = xxx).

[Action by User]

Restart CS+.

C1700001

[Message]

Failed to execute the hook event (ID = xxx).

[Action by User]

Restart CS+.

C1700002

[Message]

Failed to execute the code

[Action by User]

Restart CS+.

C1700003

[Message]

Failed to execute the script file.

[Action by User]

Restart CS+.

C1700004

[Message]

Failed to display the string.

[direct error]

[Action by User]

Restart CS+.

C1710000

[Message]

The specified name is illegal.

[Action by User]

Restart CS+. If this does not resolve the problem, reinstall CS+.

C1710001

[Message]

The specified name is already used.

[Action by User]

Restart CS+. If this does not resolve the problem, reinstall CS+.

C1710002

[Message]

Failed to read the necessary DLL.

[Action by User]

Restart CS+. If this does not resolve the problem, reinstall CS+.

C1710003

[Message]

Cannot fine the specified name.

[Action by User]

Restart CS+. If this does not resolve the problem, reinstall CS+.

C1710004

[Message]

Specified GUID is illegal.

[Explanation]

This appears when the GUID for access is illegal.

[Action by User]

Specify a correct GUID.

C1720000

[Message]

Specified GUID is illegal.

[Explanation]

This appears when access to a Bip execution instance fails.

C1720001

[Message]

Specified name is illegal.

[Explanation]

This appears when access to a Bip execution instance fails.

C1720100

[Message]

Specified GUID is illegal.

[Explanation]

This appears when access to a Pip execution instance fails.

C1720101

[Message]

Specified name is illegal.

[Explanation]

This appears when access to a Pip execution instance fails.

C1813701

[Message]

Internal error (FFWERR_BEXE_LEVEL0).

C1813702

[Message]

Internal error (FFWERR_EML_ENDCODE).

C1813703

[Message]

Internal error (FFWERR_FDT_ENDCODE).

C1813704

[Message]

Internal error (FFWERR_EML_TO_FDT).

C1813705

[Message]

Internal error (FFWERR_FDT_TO_EML).

C1813706

[Message]

Internal error (FFWERR_MONP_ILLEGALEML).